Updated code comments

pull/4717/head
Matt Visnovsky 8 months ago
parent c87ac2f043
commit 09fd816aae

@ -14,6 +14,9 @@ class SNMPMonitorType extends MonitorType {
port: monitor.port || "161",
retries: monitor.maxretries,
timeout: monitor.timeout * 1000,
// Resolve the net-snmp version identifier from monitor.snmpVersion using the `getKey` method (see utils.ts).
// If the specified version exists, use it; otherwise, default to SNMP version 2c.
version: getKey(snmp.Version, monitor.snmpVersion) || snmp.Version2c,
};
@ -38,9 +41,14 @@ class SNMPMonitorType extends MonitorType {
});
});
// Verify if any varbinds were returned from the SNMP session or if the varbind type indicates a non-existent instance.
// The `getKey` method retrieves the key associated with the varbind type from the snmp.ObjectType object.
if (varbinds.length === 0 || getKey(snmp.ObjectType, varbinds[0].type) === "NoSuchInstance") {
throw new Error(`No varbinds returned from SNMP session (OID: ${monitor.snmpOid})`);
// Varbinds succesfully returned
} else {
const value = varbinds[0].value;
// Check if inputs are numeric. If not, re-parse as strings. This ensures comparisons are handled correctly.

Loading…
Cancel
Save